GENERAL FEATURES OF SERIES D ?CASING: DN150, IP 55 (IEC 144). Case and bayonet bezel ring from AISI series 300 stainless steel drawn sheet. ?DIAPHRAGM ELEMENT Differential cell of exclusive design, without packing nor pivots. Wetted parts: -Diaphragm AISI 316 up to range 0/1,6 bar, AISI 304 over. -Gaskets NBR. -Other parts AISI 304 up to range 0/60 mbar, AISI 316 over. ?MOUNTING Surface, or 2" pipe through optional bracket. ?RANGES: 0/6 mbar to 0/10 bar (see table overleaf). ?MOVEMENT Heavy-duty, AISI series 300 stainless steel. ?DIAL Copper free (max. 0,1%) aluminium. Inalterable black numerals and graduations on white background. Scale graduation on 90° arc for range 0/6 mbar. ?POINTER Anodised duralumium with micrometer front adjustment. ?ACCURACY ( at 20 °C and zero static pressure ) Better than 1% of span ( 2% for range 0/6 mbar ). ?ZERO SHIFT ( at 20 °C and max. static pressure ) Max. ± 2% of span. ?TEMPERATURE ERROR: max ± 0,8% of span x 10 K. ?AMBIENT TEMPERATURE: ?20/+70 °C (opt. ?40/+70°C). ?OPTION execution according to Directive ATEX 94/9/EC Group II Cat. 2GD c Annex VIII